MIX6071 Laser Dust Sensor

  • Target Gas: PM2.5, PM10
  • Range :Measurable Dust Size: 0.3μm~10μm
  • Application: Air purifier,Air Quality Monitor,HAVC refrigeration

Send Email: sales@mixsen.com

Principle Introduction:

MIX6071 Laser Dust Sensor is used to measure the dust particle (Size: 0.3μm~10μm) in the environment and output the dust density real-time value (μg/m³) of PM1.0, PM2.5, PM10. The body of the sensor is designed with ultra-thin (12mm) structure for easy and diverse installation, full metal cover for electrical shielding and built-in advanced algorithm based on optical scattering technology with light source of Laser for accurate and steady output.

Feature:

laser sensor

Application:

Fresh air system
Air conditioning
Vehicle air purifier
Hand held air quality inspection

Air purifier 
Air Quality Monitor 
HAVC refrigeration 
Environment Monitoring

Technical parameters :

Item Specification
Measurable Dust Size 0.3μm~10μm
Measurement Range 0-1000ug/m³
Resolution 1ug/m³
Working Condition -15℃~60℃, 0-95%RH(non-condensing)
Storage Condition -30℃~70℃, 0-95%RH(non condensing)
Measurement Accuracy(PM2.5) 0~80μg/m³, ±8μg/m³
80μg/m³ ~ 600μg/m³,± 15%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source:Cigarette(8mg)
Measurement Accuracy(PM10) 0~100μg/m³, ±25μg/m³
100μg/m³ ~ 600μg/m³,± 25%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source: Cigarette(8mg)
Output Interval 1s
Time of first Reading ≤5s
Power Supply DC 5V±0.3V,Ripple wave<50mV
Working Current ≤90mA
Standby Current ≤50μA
Dimension 48x40x12mm
Digital output mode UART TTL 3.3V
MTTF 30000 Hours 